API / Commands / Switch PST/PGM Signal Sources
Switch PST/PGM Sources (mini Series)
Overview
Switch the input signal to PST/PGM
Devices Supported
Support all mini series
Command Structure
| Element | Attribute | Detail |
|---|---|---|
| HEAD | < | |
| TYPE | T | |
| ADDR | 0x00 | default |
| SEQN | 0x00 | default |
| CMMD | 0x75 | |
| DAT1 | 0x02/0x03 | 0x02(Set),0x03(Query) |
| DAT2 | 0x00 | Unused |
| DAT3 | 0x00~0x03 | Input port 1-4 |
| DAT4 | 0x00/0x01 | 0x00(PST),0x01(PGM) |
| CHKS | Check sum=ADDR+SN+CMD+DAT1+DAT2+DAT3+DAT4 | |
| END | > |
Example Transmit
- Set Input 1 to PST
| Command | HEAD | TYPE | ADDR | SEQN | CMMD | DAT1 | DAT2 | DAT3 | DAT4 | CHKS | END |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ASCII | < | T | 00 | 00 | 75 | 02 | 00 | 00 | 00 | 77 | > |
| HEX | 3C | 54 | 30 30 | 30 30 | 37 35 | 30 32 | 30 30 | 30 30 | 30 30 | 37 37 | 3E |
Command Sample
<T0000750200010078> // Set Input 2 to PST
<T000075020002017A> // Set Input 3 to PGM