API / Commands / Communication
Communication (mini Series)
Overview
Establish or disconnect communication with the device
Devices Supported
All mini series
Establish/Disconnect communication
Command Structure
| Element | Attribute | Detail |
|---|---|---|
| HEAD | < | |
| TYPE | T | |
| ADDR | 0x00 | default |
| SEQN | 0x00 | default |
| CMD | 0x68 | |
| DAT1 | 0x66~67 | 0x66(Set),0x67(Query) |
| DAT2 | 0x00~0x01 | 0x00(off),0x01(on) |
| DAT3 | 0x00 | Unused |
| DAT4 | 0x00 | Unused |
| CHKS | Check sum=ADDR+SD+CMD+DAT1+DAT2+DAT3+DAT4 | |
| END | > |
Example Transmit
- Disconnect
| Command | HEAD | TYPE | ADDR | SEQN | CMMD | DAT1 | DAT2 | DAT3 | DAT4 | CHKS | END |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ASCII | < | T | 00 | 00 | 68 | 66 | 00 | 00 | 00 | CE | > |
| HEX | 3C | 54 | 30 30 | 30 30 | 36 38 | 36 36 | 30 30 | 30 30 | 30 30 | 43 45 | 3E |
- Connect
| Command | HEAD | TYPE | ADDR | SEQN | CMMD | DAT1 | DAT2 | DAT3 | DAT4 | CHKS | END |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ASCII | < | T | 00 | 00 | 68 | 66 | 01 | 00 | 00 | CF | > |
| HEX | 3C | 54 | 30 30 | 30 30 | 36 38 | 36 36 | 30 31 | 30 30 | 30 30 | 43 46 | 3E |
Command Sample
<T00006866000000CE> //Disconnect communication
<T00006866010000CF> //Connect communication