API / Commands / Communication

Communication (mini Series)

Overview

Establish or disconnect communication with the device

Devices Supported

All mini series

Establish/Disconnect communication

Command Structure

ElementAttributeDetail
HEAD<
TYPET
ADDR0x00default
SEQN0x00default
CMD0x68
DAT10x66~670x66(Set),0x67(Query)
DAT20x00~0x010x00(off),0x01(on)
DAT30x00Unused
DAT40x00Unused
CHKSCheck sum=ADDR+SD+CMD+DAT1+DAT2+DAT3+DAT4
END>

Example Transmit

  • Disconnect
CommandHEADTYPEADDRSEQNCMMDDAT1DAT2DAT3DAT4CHKSEND
ASCII<T00006866000000CE>
HEX3C5430 3030 3036 3836 3630 3030 3030 3043 453E
  • Connect
CommandHEADTYPEADDRSEQNCMMDDAT1DAT2DAT3DAT4CHKSEND
ASCII<T00006866010000CF>
HEX3C5430 3030 3036 3836 3630 3130 3030 3043 463E

Command Sample

<T00006866000000CE>  //Disconnect communication
<T00006866010000CF>  //Connect communication