FAQ / 1 Series / X1 ERR Troubleshooting
X1 ERR issue troubleshooting
Overview
The X1 ERR condition should be handled as a structured hardware-plus-firmware check. Do not jump straight to repeated firmware updates until the mechanical checks are complete.
Applies to
X1
Recommended sequence
- Record the software version and serial number from Menu > System > Version and Menu > System > SN.
- Inspect the bottom-cover screws. A screw without the correct foot can create a short circuit.
- Check the sub-firmware version. If it reports 0.01, perform a factory reset and reboot.
- If the issue remains, run the firmware update twice, then factory reset and reboot again.
- Confirm the MCU/COM version matches the firmware branch you are loading.
Firmware mapping from the source guidance
- MCU/COM V1.1 systems were paired with X1 firmware V1.56.
- MCU/COM V1.2 or V1.3 systems were paired with X1 firmware V2.44.
Escalation point
- If the mechanical check, firmware match, double update, reset, and reboot do not clear the issue, move the case to direct technical support rather than repeating the same cycle.
References
- X1 firmware branch for MCU/COM V1.1: https://rgblinkw3media9490.blob.core.windows.net/product-images/documents/support-faq/01_Latest_Firmware.zip
- X1 firmware branch for MCU/COM V1.2 and V1.3: https://rgblinkw3media9490.blob.core.windows.net/product-images/documents/support-faq/01_Latest_Firmware.zip