RGBlink
← 返回支持中心
proAV

系统集成与商业项目支持

查看支持范围

如问题涉及处理器控制、视频路由、安装设计、集成问题或 proAV 设备 OpenAPI,请从这里开始。

  • 商业安装、处理器、切换器、定标器和分发系统
  • proAV 设备 OpenAPI 控制问题
  • 已落地项目中的系统集成、部署和故障排查

开始支持对话

告诉我们您的设备型号和问题,或选择一个示例问题。

支持知识

从左侧目录选择文章后,在此查看完整内容。

FAQ / IC2 / IC2 Sync And Group Setup

IC2 synchronization and group management

Overview

IC2 master, slave, and auto settings are for timing synchronization. They do not enable a separate switching feature.

Applies to

IC2 transmitters and receivers

How master, slave, and auto work

  • The timing logic is intended to keep receivers frame-synchronized by adjusting clock frequency.
  • Only one master TX and one master RX should exist in the overall system.
  • The feature is for timing synchronization only.

Single-switch network design

  • Set one RX as master and the remaining RX units as slave.
  • Turn on Auto for all receivers in XPOSE.
  • If the master powers off, a slave can be selected automatically to take over.
  • Apply the same approach on the TX side.

Multi-switch network design

  • Set one RX as master and the remaining RX units as slave.
  • Turn off Auto for all receivers.
  • Auto is avoided here because each switch domain can try to elect its own master after a full power cycle.
  • If the fixed master powers off in this design, synchronization issues can appear.

Other operational notes

  • Group selection in Input Management is primarily for fast layout management when you have more than four transmit sources.
  • Custom layout work should be done in Video Management.
  • Both mic-level and line-level audio can be used on audio input, though line level is generally more effective.
  • Factory reset is available under Advanced after selecting the target IC node.
  • IP cameras are added as input nodes by entering the camera IP plus main and sub streams manually.